60 Core High Voltage Transmission Lines OPGW Optical Ground Wire G.655

Product Details

Place of Origin: CHENGDU, CHINA

Brand Name: HUIYUAN

Certification: ISO9001

Model Number: OPGW-60B1.3

Payment & Shipping Terms

Minimum Order Quantity: 4KM

Price: Negotiable

Packaging Details: Wooden drum

Delivery Time: 5 to 20 working days

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability: 5000km/month

Get Best Price
High Light:

60 Core high voltage transmission lines

,

high voltage transmission lines G.655

,

OPGW Optical Ground Wire G.655

Product Name:
60 Core High Voltage Power Transmission Line OPGW Optical Ground Wire
Fiber Count:
60F
Fiber:
G.655
Structure:
SS Tube
Application:
Outdoor Communication
Strength Member:
Aluminum Steel Wire
Packing:
Iron Wooden Drum
Operating Temperature:
-40 ~ +60 C
Product Name:
60 Core High Voltage Power Transmission Line OPGW Optical Ground Wire
Fiber Count:
60F
Fiber:
G.655
Structure:
SS Tube
Application:
Outdoor Communication
Strength Member:
Aluminum Steel Wire
Packing:
Iron Wooden Drum
Operating Temperature:
-40 ~ +60 C
60 Core High Voltage Transmission Lines OPGW Optical Ground Wire G.655

 
60 Core High Voltage Power Transmission Line OPGW Optical Ground Wire
 
Description
 
OPGW is primarily used by the electric utility industry, placed in the secure topmost position of the transmission line where it “shields” the all-important conductors from lightning while providing a telecommunications path for internal as well as third party communications. Optical Ground Wire is a dual functioning cable, meaning it serves two purposes. It is designed to replace traditional static / shield / earth wires on overhead transmission lines with the added benefit of containing optical fibers which can be used for telecommunications purposes. OPGW must be capable of withstanding the mechanical stresses applied to overhead cables by environmental factors such as wind and ice. OPGW must also be capable of handling electrical faults on the transmission line by providing a path to ground without damaging the sensitive optical fibers inside the cable.
 
Technical specification
 

Specification
Fiber Count Diameter Weight RTS Short Circuit
(mm) (kg/km) (KN) (KA2s)
OPGW-89[55.4;62.9] 24 12.6 381 55.4 62.9
OPGW-110[90.0;86.9] 24 14 600 90 86.9
OPGW-104[64.6;85.6] 28 13.6 441 64.6 85.6
OPGW-127[79.0;129.5] 36 15 537 79 129.5
OPGW-137[85.0;148.5] 36 15.6 575 85 148.5
OPGW-145[98.6;162.3] 48 16 719 98.6 162.3

 
Cable structure
 
60 Core High Voltage Transmission Lines OPGW Optical Ground Wire G.655 0

Features

 

1. Small diameter, low weight reduces retrofit impact
2. Hermetically sealed stainless steel tubes provide mechanical and thermal protection for fibers
3. Thick-walled aluminum pipe provides crush resistance and boosts fault current rating
4. Replacement with ACS wires improves lightning resistance
5. Lower wind and ice loads put less load on structures
6. Fiber grouped in bundles of 12 for ease of splicing

 

Standard drum length

 

2000m/drum & 4000m/drum
Fiber specification
 

Characteristics Specified Values Units
Geometric characteristic
Cladding diameter 125.0±1.0 µm
Cladding non-circularity ≤1.0 %
Coating diameter 245.0±10.0 µm
Coating-cladding concentricity error ≤12.0 µm
Coating non-circularity ≤6.0 %
Core-cladding concentricity error ≤0.8 µm
Mechanical characteristic
Curling ≥4 m
Proof stress ≥0.69 GPa
Coating strip force Average value 1.0-5.0 N
Peak value 1.3-8.9 N
Macro bending loss Ф60mm, 100 circles, at 1550nm ≤0.05 dB
Ф32mm, 1 circles, at 1550nm ≤0.05 dB

 
Test
 

Item Test Method Requirements
  IEC 60794-1-2-E1  
  Load: according to cable structure 40%RTS no additional fibre strain(0.01%), no additional attenuation (0.03dB).
  Sample length: no less than 10m, linked length no less than100m 60%RTS fibre strain≤0.25%,additional attenuation≤0.05dB
Tension Duration time: 1min (No additional attenuation after test).
  IEC 60794-1-2-E3  
  Load: according to above table, three points Additional attenuation at 1550nm ≤0.05dB/fibre; No damage to the elements
Crush Duration time: 10min  
  IEC 60794-1-2-F5B No water leakage.
  Time : 1 hour Sample length: 0.5m
Water Penetration Water height: 1m
  IEC 60794-1-2-F1 The change in attenuation coefficient shall be less than 0.1dB/km at 1550nm.
  Sample length: No less than 500m
  Temperature range: -40℃ to +65℃
Temperature Cycling Cycles: 2
  Temperature cycling test dwell time: 12h

Factory & office
60 Core High Voltage Transmission Lines OPGW Optical Ground Wire G.655 1
Production line
60 Core High Voltage Transmission Lines OPGW Optical Ground Wire G.655 2

Team

60 Core High Voltage Transmission Lines OPGW Optical Ground Wire G.655 3